002 Steel Failure in Tension (Part02)

The given embedded plate is selected from Peikko Welda-300x300x165. Determines the tension forces in the anchor bolts and the plate length under compression. The wall thickness is 400mm made of C30/37 concrete class. The loads applied to the plate are given in design format (Ed), as shown in the figure.

Link to the description and detailed solution notes: Download