This video will teach us how to determine the lap length of the reinforced concrete element according to Eurocode 1992-1-1. In the end, a straightforward example is provided to determine the required bar length. The example of the video:
In the previous video, we determined the anchorage length of the reinforcement of a column. Those 8T25 need to be extended from the construction joint of the foundation top level until the column reinforcement is placed and ready to be concreted. Determine the required lap length according to Eurocode 1992-1-1. Concrete class C35/45 and steel AH500.
Link to the description and detailed solution notes: Download